Thermal conductivity measurement

There are a number of possible ways to measure thermal conductivity, each of them suitable for a limited range of materials, depending on the thermal properties and the medium temperature. Two classes of methods exist to measure the thermal conductivity of a sample: steady-state and non-steady-state methods.

Contents

Steady-state methods

In general, steady-state techniques perform a measurement when the temperature of the material measured does not change with time. This makes the signal analysis straightforward (steady state implies constant signals). The disadvantage is that a well-engineered experimental setup is usually needed.

In geology and geophysics, the most common method for consolidated rock samples is the divided bar. There are various modifications to these devices depending on the temperatures and pressures needed as well as sample sizes. A sample of unknown conductivity is placed between two samples of known conductivity (usually brass plates). The setup is usually vertical with the hot brass plate at the top, the sample in between then the cold brass plate at the bottom. Heat is supplied at the top and made to move downwards to stop any convection within the sample. Measurements are taken after the sample has reached to the steady state (with zero heat gradient or constant heat over entire sample), this usually takes about 10 minutes.

Transient methods

The transient techniques perform a measurement during the process of heating up. The advantage is that measurements can be made relatively quickly. Transient methods are usually carried out by needle probes.

Non-steady-state methods to measure the thermal conductivity do not require the signal to obtain a constant value. Instead, the signal is studied as a function of time. The advantage of these methods are that they can in general be performed more quickly, since there is no need to wait for a steady-state situation. The disadvantage is that the mathematical analysis of the data is in general more difficult.

Transient plane source method

Transient Plane Source Method, a plane sensor, a special mathematical model describing the heat conductivity, combined with precise electronics, enables the method to be used to measure Thermal Transport Properties. It covers a thermal conductivity range of 4–5 orders of magnitude and can be used for measuring various kinds of materials, such as solids, powder, liquid, paste and thin films etc. In 2008 it was approved as an ISO-standard for measuring thermal transport properties of polymers (November 2008). This TPS standard also covers the use of this method to test both isotropic as well anisotropic materials.

This same Transient Plane Source is able to test in two basic formats; sensor sandwiched between two pieces of same sample or single sided, where only one piece of sample is required.

The probe is a flat sensor with a continuous double spiral of electrically conducting nickel (Ni) metal etched out of thin foil and clad between two layers of polyimide film Kapton. The thin Kapton provides electrical insulation and mechanical stability to the sensor. The sensor is placed between the surfaces of two sample pieces of the sample to be measured. During the measurement a current passes through the nickel and creates an increase in temperature. The heat generated dissipates through the sample on either side of the sensor at a rate depending on the thermal transport characteristics of the material. By recording temperature vs. time response in the sensor, the characteristics of the material can be calculated.

Modified transient plane source (MTPS) method

A variation of the above method is the Modified Transient Plane Source Method (MTPS) developed by Nancy Mathis of the University of New Brunswick and commercialized through her company Mathis Instruments Ltd (now C-Therm Technologies Ltd.). The device uses a one-sided, interfacial, heat reflectance sensor that applies a momentary, constant heat source to the sample. The difference between this method and traditional transient plane source technique described above is that the heating element is supported on a backing, which provides mechanical support, electrical insulation and thermal insulation. This modification provides a one-sided interfacial measurement in offering maximum flexibility in testing liquids, powders, pastes and solids.

Transient line source method

The physical model behind this method is the infinite line source with constant power per unit length. The temperature profile T(t,r) at a distance r at time t is as follows

T(t,r) = \frac{Q}{4 \pi k} \mathrm{Ei} \left( \frac{r^2}{4 a t} \right)

where

Q is the power per unit length, in [W·m−1]
k is the thermal conductivity of the sample, in [W·m−1·K−1]
\mathrm{Ei}(x) is the exponential integral, a transcendent mathematical function
r is the radial distance to the line source
a is the thermal diffusivity, in [m2·s−1]
t is the amount of time that has passed since heating has started, in [s]

When performing an experiment, one measures the temperature at a point at fixed distance, and follows that temperature in time. For large times, the exponential integral can be approximated by making use of the following relation

\mathrm{Ei}(x) = - \gamma - \ln (x) %2B O(x)

where

\gamma \approx 0.577 is the Euler gamma constant

This leads to the following expression

T(t,r) = \frac{Q}{4 \pi k} \left\{ -\gamma -\ln \left( \frac{r^2}{4 a t} \right) %2B \ln (t) \right\}

Note that the first term in the brackets on the RHS is a constant, while the second term goes as the inverse of time and therefore drops out fairly quickly. Thus if the probe temperature is plotted versus the natural logarithm of time, the thermal conductivity can be determined from the slope given knowledge of Q, if the initial data, before the diffusivity term becomes negligible, are ignored. Typically this means ignorming the first 60 to 120 seconds of data and measuring for 600 to 1200 seconds.

3ω-method

One popular technique for thermoelectric materials is a 3ω-method, in which thin metal strip evaporated on the sample acts as heat source and a thermometer. The heater is driven with AC current at frequency ω, which causes heat source to oscillate at frequency 2ω. By monitoring AC voltage as a function of the frequency of the applied AC current thermal conductivity can be determined. The measured voltage will contain both ω and 3ω components, because the Joule heating of the film causes small perturbation to its resistance with frequency 2ω as stated in the following equation V=IR=I_0e^{i\omega t}\left (R_0%2B\frac{\partial R}{\partial T}\Delta T \right )=I_0e^{i\omega t}\left (R_0%2BC_0e^{i2\omega t} \right ), C0 is constant. Thermal conductivity is determined by the linear slope of ΔT vs. log(ω) curve. The main advantages of the 3ω-method are minimization of radiation effects and easier acquisition of the temperature dependence of the thermal conductivity than in the steady-state techniques. Although some expertise in thin film patterning and microlithography is required, this technique is considered as the best pseudo-contact method available. [1](ch23)

Other methods

For good conductors of heat, Searle's bar method can be used[2]. For poor conductors of heat, Lees' disc method can be used[3]. Also

Thermoreflectance

Thermoreflectance is a method by which the thermal properties of a material can be measured, most importantly thermal conductivity. This method can be applied most notably to thin film materials (up to hundreds of nanometers thick), which have properties that vary greatly when compared to the same materials in bulk. The idea behind this technique is that once a material is heated up, the change in the reflectance of the surface can be utilized to derive the thermal properties. The reflectivity is measured with respect to time, and the data received can be matched to a model which contain coefficients that correspond to thermal properties.

Measuring devices

A thermal conductance tester, one of the instruments of gemology, determines if gems are genuine diamonds using diamond's uniquely high thermal conductivity.

Standards

References

  1. ^ Rowe, David Michael. Thermoelectrics handbook : macro to nano / edited by D.M. Rowe. Boca Raton: CRC/Taylor & Francis, 2006. ISBN 0-8493-2264-2
  2. ^ http://media.paisley.ac.uk/~davison/labpage/searle/searle.html
  3. ^ http://academia.hixie.ch/bath/Thermal/home.html
  4. ^ IEEE Standard 442-1981- IEEE guide for soil thermal resistivity measurements, doi:10.1109/IEEESTD.1981.81018 
  5. ^ IEEE Standard 98-2002 - Standard for the Preparation of Test Procedures for the Thermal Evaluation of Solid Electrical Insulating Materials, doi:10.1109/IEEESTD.2002.93617 
  6. ^ ASTM Standard D5334-08 - Standard Test Method for Determination of Thermal Conductivity of Soil and Soft Rock by Thermal Needle Probe Procedure, doi:10.1520/D5334-08 

External links